Indicator Diagnostic Button: Difference between revisions
Jump to navigation
Jump to search
(Initial creation) |
No edit summary |
||
| Line 9: | Line 9: | ||
== Operation == | == Operation == | ||
The button has three states: | |||
* normal | |||
* all OFF | |||
* all ON | |||
Cycling through these states is accomplished by pressing MPrT together with the station button. Each time MPrT + station button are pressed, the diagnostic status changes. You will need to do this combination three times to return the panel to the normal state. | |||
Revision as of 21:13, 16 February 2016
Contents | FAQ | Manual | General Tips and Tricks | Change Log | Multiplayer Manual | Line Operations Manual | Voice Communications | Change Log | Developers pages
Purpose
The MPrT button (Meldeprüftaste or indicator check button) is a DUS501 button is a diagnostic tool. With it, the dispatcher can verify that the panel lights are working correctly.
Operation
The button has three states:
- normal
- all OFF
- all ON
Cycling through these states is accomplished by pressing MPrT together with the station button. Each time MPrT + station button are pressed, the diagnostic status changes. You will need to do this combination three times to return the panel to the normal state.