OLE Controls (Germany)

From SignalWiki
Revision as of 07:38, 18 January 2011 by Signalsoft (talk | contribs)

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Typical Overhead Line Equipment (OLE) control panels in Germany consist of two buttons per circuit breaker. These buttons are labelled "E" for "on", and "A" for "off". A blue label beneath the buttons indicates the breaker number.

If the breaker is disconnected, pressing the "E" button closes the breaker. Conversely, if the breaker is connected, pressing the "A" button opens the breaker. If the breaker is closed and excess current is detected, the breaker will open automatically and is said to be "tripped."

Additionally, these controls have caps that are placed over top of the buttons to prevent accidental operation in cases where there may be engineering work underway. These caps are yellow and have "Nicht Schalten" printed on them.