Control Monitor Sp Dr S 600: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
|||
| Line 10: | Line 10: | ||
*[[File:DET-zoomout.png|Zoom out]] : Zoom out | *[[File:DET-zoomout.png|Zoom out]] : Zoom out | ||
=== Keys to execute commands === | === Keys to execute commands === | ||
| Line 34: | Line 35: | ||
|- | |- | ||
|} | |} | ||
=== Commands for setting routes === | === Commands for setting routes === | ||
| Line 70: | Line 72: | ||
| '''F,U''',123.345 || Sets an alternative route from signal 123 towards signal/exit track 345, where no overhead lines are available | | '''F,U''',123.345 || Sets an alternative route from signal 123 towards signal/exit track 345, where no overhead lines are available | ||
|} | |} | ||
=== Simple commands === | === Simple commands === | ||
| Line 155: | Line 158: | ||
| ANN-4711,575 + [[File:DET-ZNL.png|inline|27px|ZNL]] || Refuse train 4711 that is offered on track 575 | | ANN-4711,575 + [[File:DET-ZNL.png|inline|27px|ZNL]] || Refuse train 4711 that is offered on track 575 | ||
|} | |} | ||
=== Special commands === | |||
The following commands are computer-specific. Those are necessary, as the PC does not have the special keyboard as present on a real signal box. | |||
{| cellpadding="10" cellspacing="0" border="1" | |||
|- | |||
| '''Input''' || '''Function''' | |||
|- | |||
| [memory block number] / || Change to memory block. By entering '''3''' and '''/''' '''(Numeric keyboard)''' memory block 3 becomes the active memory block. | |||
|- | |||
| [Line number of active memory block] || Entering '''3''' (Numeric keyboard) executes the command on line '''3''' of the active memory block. | |||
|- | |||
| * '''(Numeric keyboard)'''|| Contents of the command line are stored in the first unused line of the active memory block. | |||
|- | |||
| Left Arrow || Change to previous 6 memory blocks | |||
|- | |||
| Right Arrow || Change to next 6 memory blocks | |||
|- | |||
| Space || Control monitor window to the front and activate | |||
|- | |||
| Escape || Deactivate control monitor window (allowing other keyboard input resp. commands) | |||
|- | |||
|} | |||
{{EnglishNavBottom}} | {{EnglishNavBottom}} | ||
Revision as of 10:11, 6 July 2014
Page is under construction. Information is subject to change.
Contents | FAQ | Manual | General Tips and Tricks | Change Log | Multiplayer Manual | Line Operations Manual | Voice Communications | Change Log | Developers pages
Data Entry Keyboard
Keys to execute commands
| Key | Function |
| Execute and erase command from command line | |
| Execute and store command into active memory block | |
| Store input into active memory block | |
| Entered number (1 through 6) selects the corresponding memory block | |
| Entered number clears the corresponding line in the active memory block | |
| Clear command line | |
| Send train number | |
| Clear train number |
Commands for setting routes
These commands are applied by pressing
or
, or can be stored in the active memory block by applying
.
| Input | Function |
| 123.345 | Sets train route from signal 123 to signal/exit track 345 |
| 123-345 | Sets shunt route from signal 123 to signal/exit track 345 |
Extra codes for setting train routes
| Input | Function |
| F,123.345 | Sets train route from signal 123 to signal/exit track 345, where no overhead lines are available |
| 123.345K | Sets train route from signal 123 to signal/exit track 345, without or short overlap |
| 123.345L | Sets train route from signal 123 to signal/exit track 345, with diverging overlap to the left |
| 123.345R | Sets train route from signal 123 to signal/exit track 345, with diverging overlap to the right |
| M,103.P3 | Sets route from middle switch starting at signal 103 towards signal P3 |
| U,123.345 | Sets an alternative route from signal 123 towards signal/exit track 345 |
| F,U,123.345 | Sets an alternative route from signal 123 towards signal/exit track 345, where no overhead lines are available |
Simple commands
These commands are applied by pressing
or
, or can be stored in the active memory block by applying
.
Example: WU,123 = Throw switch 123.
| Command | Action |
| Switches | |
|---|---|
| WU | Throw switch |
| WUS | Manually locks a switch to prevent it from being thrown |
| WUE | Manually unlocks a switch to prevent it from being thrown. |
| WPH | Show switch position shortly. |
| FRTE | Revokes a part of a train route. (Reminder: First operate start signal with HS/HaGT!) |
| Signals | |
| HS | Puts a signal to stop |
| SS | Lock signal |
| Routes | |
| FRTG | Revokes a complete train route. (Reminder: First operate start signal with HS/HaGT!) |
| SBA | Enables fleeting of a signal. |
| SBE | Disables fleeting of a signal. |
| Blocks | |
| EA | Used to set a block direction towards your signal box |
| EL | Used to cancel pre-setting a block direction towards your signal box. |
| Panel | |
| AE,1 | Show all switch positions |
| AA,1 | Disable showing all switch positions |
| NE,1 | Sets (outside) signal brightness to night mode |
| TE,1 | Sets (outside) signal brightness to day mode |
Entering Train numbers
These commands are executed by applying
or
.
Special commands
The following commands are computer-specific. Those are necessary, as the PC does not have the special keyboard as present on a real signal box.
| Input | Function |
| [memory block number] / | Change to memory block. By entering 3 and / (Numeric keyboard) memory block 3 becomes the active memory block. |
| [Line number of active memory block] | Entering 3 (Numeric keyboard) executes the command on line 3 of the active memory block. |
| * (Numeric keyboard) | Contents of the command line are stored in the first unused line of the active memory block. |
| Left Arrow | Change to previous 6 memory blocks |
| Right Arrow | Change to next 6 memory blocks |
| Space | Control monitor window to the front and activate |
| Escape | Deactivate control monitor window (allowing other keyboard input resp. commands) |